Publishing IC 2.2 handlers in IC 2.4x

If you wrote or modified IC 2.2 handlers, you must first save them in IC 2.3x or greater before you can publish them in IC 2.4x. Depending on the content of the original handler, you may receive Interaction Designer error messages indicating that a tool's parameters and/or exit paths have changed since the previous release. This error message will tell you the offending tool's Step Label and Node ID, and attempt to explain the problem with an error message.

You cannot publish this handler until you correct the problem and save it in the newer version. Use the Step Label, Node ID, and error message text to locate the step and diagnose the problem. Make any changes that are necessary to solve the problem, such as creating a variable to contain the value of the parameter, or creating a link from the new exit path. Then save the handler and try publishing it again.