Feedback

  • Contents
 

Event Log Messages

The following table describes various event messages that the Process Automation Server subsystem can record in the Windows Event Log on the Windows server.

Event ID Type Message details

41043

Error

Process Automation Server cannot start because the database connection string for Workflow storage is missing.

41044

Informational

Process Automation Server is attempting to use the default CIC database for Workflow storage. The preferred method is to provide a CIC Data Source named %1 to direct the Workflow storage to the preferred database.

41045

Error

Process Automation Server is attempting to open the storage database, but the connection has failed. For more information about the error, see the subsystem log.

41046

Error

Process Automation Server is attempting to use the storage database, and executing a required stored procedure failed. It is likely that either the Process Automation Server tables and procedures don't exist in that database, or that you didn't set the permission to execute the procedures properly. For more information about the error, see the subsystem log.