Assembly: ININ.IceLib.Interactions (in ININ.IceLib.Interactions.dll) Version: 0.0.0.0 (22.3.0.218)
Syntax
C# |
---|
public void ParkAsync( QueueId target, AsyncCompletedEventHandler completedCallback, Object userState ) |
Visual Basic |
---|
Public Sub ParkAsync ( _ target As QueueId, _ completedCallback As AsyncCompletedEventHandler, _ userState As Object _ ) |
Parameters
- target
- Type: ININ.IceLib.Interactions..::..QueueId
The queue to which to transfer. The QueueType member must be either User, Station, or Orbit.
- completedCallback
- Type: System.ComponentModel..::..AsyncCompletedEventHandler
The callback to invoke when the asynchronous operation completes.
- userState
- Type: System..::..Object
An optional object that contains state information for this request. This object is a way for the caller to store context information which will be provided to the AsyncCompleted event. If no context information is desired then nullNothingnullptra null reference (Nothing in Visual Basic) may be supplied.
Remarks
When completed, the completedCallback delegate is invoked on a thread appropriate to the application-model, such as the GUI thread in a UI application. The Error property of the AsyncCompletedEventArgs-derived object passed to the delegate will contain any exceptions thrown while executing the asynchronous task. See the synchronous version of this method for more detailed error information. For more information on async method calls, see How Async Calls Work.
This method will raise the PerformingAction event and (if the action was not cancelled) the PerformedAction event. When those events are raised, the two events' arguments (ActionParameters and ActionParameters, respectively) will contain an entry for Target.
Exceptions
Exception | Condition |
---|---|
System..::..ArgumentNullException | A parameter is nullNothingnullptra null reference (Nothing in Visual Basic). |
System..::..ArgumentException | An invalid QueueId was used as a parameter. |
System..::..ArgumentException | The target queue type is not valid for this operation. |
Version Information
For 4.0, supported for IC Server version 4.0 GA and beyond.